8

TROUBLESHOOTING GUIDE

CONDITION POSSIBLE

CAUSE

CORRECTION

OIL LEAKS FROM
WINCH

Seals damaged or worn Replace seal.

Too much oil

Drain excess oil. Refer to IN-
STRUCTIONS FOR OVERHAUL,
pg. 16.

Damaged gasket

Replace gasket.

Damaged brake shaft
seal

Replace brake, check back
pressure to motor. If back

pressure is more than 50 PSI,
reduce back pressure or add
external case drain line.

WINCH RUNS TOO
SLOW

Low flow rate

Check flow rate. Refer to Hy-

draulic Systems Performance,
page 4.

Hydraulic motor worn
out

Replace motor.

Clutch not disengaged

Check air pressure to clutch

cylinder 100 PSI minimum
required. Refer to drawing
page 20-21 for more informa-
tion.

Excessive air pressure to
cable tensioner

Reduce air pressure to ten-
sioner.

BRAKE WILL NOT
RELEASE

Brake line disconnected
or blocked

Check brake function. Refer to
page 16

LOAD LOWERS
TOO FAST

Hydraulic lines to

counter-balance valve
incorrectly installed and/
or cartridge plug position
incorrect for drum rota-

tion direction to reel
cable in.

Refer to pages 20-21 for cor-
rect installation.

CABLE DRUM
WILL NOT
FREESPOOL