Serial Communication, cont’d

System 7SC • Serial Communication

4-8

The syntax for setting a special function is __ *

X?

# where __ is the function number and

X?

is the value.

To view a function’s setting, use __#, where __ is the function number. In the following table the values of
the

X?

variable are different for each command/function. These values are given in the rightmost column.

Command/response table for special function SIS commands

Command

ASCII Command Response

X?

values

(host to switcher)

(switcher to host)

and additional descriptions

Delay times

Power on delay

1 *

X?

#

WarmUp*

X?

0 = 0 seconds,
1 = 2 seconds,
2 = 4 seconds,
... in 2 second steps up to
150 = 300 seconds (5 minutes).

Example:

1*8#

WarmUp*08

Example: set a 16 second power on delay

Example:

1#

WarmUp*023

Example:

view the power on delay

setting.

Power off delay

2 *

X?

#

CoolDown*

X?

0 = 0 seconds,
1 = 2 seconds,
2 = 4 seconds,... in 2 second
steps up to 150 = 300 seconds.

Example:

2*23#

CoolDown*023

Example:

set a 46 second power off

delay.

RGB delay

(Triple-Action Switching)

3 *

X?

#

RGBDly*

X?

0 = 0.0 seconds (default), 1 = 0.5
seconds, 2 = 1.0 seconds,
... in ½ second steps up to
10 = 5.0 seconds

Example:

3*7#

RGBDly*07

Example: 3.5 second RGB delay

Room relays

Room relay 1 mode/timing

4 *

X?

#

Rly1Tm*

X?

0 = toggle mode (press on/off),
1 = momentary,

1

/

8

second long,

2 = momentary, ¼ second long,
3 = momentary,

3

/

8

second long,

... in

1

/

8

second steps up to

16 = 2.0 seconds

Example:

4*15#

Rly1Tm*15

Example:

momentary, 1.875 sec. long

Room relay 2 mode/timing

5 *

X?

#

Rly2Tm*

X?

0 = toggle mode (press on/off),
1 = momentary,

1

/

8

second long,

2 = momentary, ¼ second long,
3 = momentary,

3

/

8

second long,

... in

1

/

8

second steps up to

16 = 2.0 seconds

Example:

5*8#

Rly2Tm*08

Example:

momentary, 1.0 sec. long

Scaler settings

Scaler output sync format

6 *

X?

#

SyncOut*

X?

0 = RGBHV (default)
1 = RGBS
2 = RGsB (sync on green, SOG)

Example:

6*1#

SyncOut*1

Example: RGBHV sync output

Scaler output polarity

7 *

X?

#

SyncPol*

X?

0 = H-/V- (default)
1 = H-/V+
2 = H+/V-
3 = H+/V+

Example:

7*1#

SyncPol*1

Example: H-/V+ sync polarity

Blue screen

(blue & sync output only)

8*

X?

#

Blu*

X?

0 = off

(default) (RGB & sync output)

1 = on

(blue video & sync output only)

Example:

8*1#

Blu*1

Example:

blue & sync output for setup