Example – Warner Electric PB-1525 User Manual
Page 11
11
Warner Electric • 800-825-9050
P-209 • 819-0517
PB-1000 Brake–Heavy Duty
Drawing I-25587
How to Order:
1. Specify Bore Size for Item 2.
2. Specify Inside Mounted for Items 5A and 6A
or Outside Mounted for Items 5B and 6B.
3. Specify Voltage for Item 6A or 6B.
4. See P-1234 for Power Supplies.
Example:
PB-1000 Brake per I-25587 - 90 Volt, 1-1/2" Bore,
Inside Mounted
These units, when used in conjunction with the cor-
rect Warner Electric conduit box, meet the stan-
dards of UL508 and are listed under guide card
#NMTR, file #59164. These units are CSA certified
under file #LR11543.
PB-1000, H.D.
Item
Description
Part Number
Qty.
1
Armature Assembly
5322-111-002
1
1-1
Armature
5322-111-036
1
1-2
Splined Adapter
104-0009
1
1-3
Autogap Accessory
5322-101-004
1
1-4
Screw
797-0272
3
1-5
Locknut
661-0004
3
2
Bushing
1/2" to 1-1/2" Bore
3/4" to 2-11/16" Bore
180-0026 to 180-0056* 1
3
Splined Hub
540-0062
1
4
Retainer Ring
748-0007
1
5A
Mounting Accessory - I.M.
5321-101-001
1
5B
Mounting Accessory - O.M.
5321-101-002
1
6A
Magnet - Inside Mounted
1
6 Volt
5312-631-004
24 Volt
5312-631-005
90 Volt
5312-631-006
†90 Volt LK Facing
5312-631-001
6A-1
Terminal Accessory
5311-101-001
1
6B
Magnet - Outside Mounted
1
6 Volt
5312-631-011
24 Volt
5312-631-013
90 Volt
5312-631-012
†90 Volt LK Facing
5312-631-002
PB-1000, H.D.
Item
Description
Part Number
Qty.
6B-1
Terinal Accessory
5311-101-001
1
7
Conduit Box
5200-101-011
1
*See page 20 for specific part numbers. †Optional LK facing
available.
1
Shipped Assembled
2
3
5A
4
5B
6A
6A-1
6B
6B-1
7
1-3
1-4
1-2
1-1
1-5
7