Warner Electric PB-1525 User Manual
Page 4
4
Warner Electric • 800-825-9050
P-209 • 819-0517
These units are shipped with the armature, splined
armature adapter, and autogap already assembled.
The splined hub, retainer ring, and bushing are
shipped as separate parts.
Follow these instructions to assemble the armature
and splined hub:
Step 1
Place the armature-splined adapter assembly on a
flat surface with the segmented side up.
Step 2
Push the splined hub, with the retainer ring groove
down, through the autogap spring and splined
armature adapter. (See Figure 4.)
Step 3
Turn the armature-adapter assembly over, and
insert the retainer ring in the groove. (See
Figure 5.)
Step 4
Slide the armature-adapter assembly up against
the retainer ring.
Step 5
Insert the bushing into the retainer ring side of the
splined hub. The clearance holes in the bushing
flange should line up with the tapped holes in the
splined hub. (See Figure 6.)
D. Mounting the Armature and Hub
Assembly
1. Slide the complete armature and hub
assembly onto the shaft until the armature face
touches the magnet face. (See Figure 7.)
Figure 4
Figure 5
Figure 6
Figure 3