Programming – Warner Electric CBC-1000 User Manual
Page 14
12
Warner Electric • 800-825-9050
P-275 • 819-0496
LINE
DISPLAY
DESCRIPTION
OPTIONS
DEFAULT
1
b d .
Initial Braking Distance - - - -
2 5
The first brake distance used by the
CBC-1000 at power-up.
2
b d . Au E . # of Cycles Averaged 1 - 9
3
The number of cycles used for the running
average of brake distance.
3
c c .
Correction Constant
- . - - - -
0 . 5000
The scaling factor for the front panel display
(0.5000 for display in pulses).
4
d P .
Decimal Point
off, .0, .00, .000
oFF
Number of decimal places displayed. Affects
all distance values in other registers.
5
F r S t.
Front Panel Reset
on - off
on
Enables or disables front reset in the RUN
Mode.
6
P L o c .
Front Panel Lock
on - off
oFF
“On” enables and “Off” disables changing
MOV PST, E.W., and BCH PST while running.
7
C r E t .
Count Retention
on - off
on
Retains system position during power off.
8
A r S t .
AUTO Reset
on - off
oFF
Select Absolute (ON) or Incremental (OFF)
mode of operation.
9
o 1 .
Start Output
00.00 to 99.99
00 . 10
The duration (momentary or latched) of the
Start Output in seconds. For latched input,
enter all zeros or press
.
10
o 2 .
Early Warning Output 00.00 to 99.99
00 . 10
The duration (momentary or latched) of the
Early Warning output in seconds.
11
o 3 .
Brake on Output
00.00 to 99.99
00 . 10
The duration (momentary or latched) of the
Brake On output in seconds.
12
o 4 .
Zero Speed Output
00.00 to 99.99
00 . 10
The duration (momentary or latched) of the
Zero Speed output in seconds.
13
o 5 .
Zero Speed + Delay 1 00.00 to 99.99
00 . 10
The duration (momentary or latched) of the
Zero Speed + Delay 1 output in seconds.
14
o 6 .
Zero Speed + Delay 2 00.00 to 99.99
00 . 10
The duration (momentary or latched) of the
Zero Speed + Delay 2 output in seconds.
15
o 8 .
Batch Counter Reset 00.00 to 99.99
LATCH
Momentary for automatic (internal) reset or
latched for manual (operator) reset.
16
d 1 .
Delay Time 1
00.00 to 99.99
0 . 50
The delay time for Zero Speed + Delay 1
output in seconds.
17
d 2 .
Delay Time 2
00.00 to 99.99
1 . 00
The delay time for Zero Speed + Delay 2
output in seconds.
18
0 5 P .
Zero Speed Window 01, .05,.10, .25 sec. 10
The time window in seconds to determine
Zero Speed, Zero Speed equals no pulses
received within window.
19
5
Start Command
1-6
- - - - - -
Releases latched outputs at the start
Release Outputs
command. Press 1-6 on the front panel to
release or drop output.
20
L
Move Preset Release 1-6
- - - - - -
Releases latched outputs at the move preset.
Outputs
Press 1-6 on the front panel to release output
or drop output.
RESET
CLEAR
Programming