Warner Electric CBC-150 User Manual
Cbc-150 series clutch/brake controls, Installation and operation manual
Installation and Operation Manual
P-239-21
819-0477
CBC-150 Series Clutch/Brake Controls
Introduction
The Warner Electric CBC-150 series is a family
of clutch/brake controls which conveniently
mount to the conduit box cover of the Electro
Module line of electromagnetic clutches and
brakes. The CBC-150 series controls are dual
channel devices available in two models:
CBC-150-1
120 VAC input
CBC-150-2
220/240 VAC input
These controls are designed for operation of
all Warner Electric 90 VDC clutches and brakes.
They should not, however, be used to directly
power Warner Electric permanent magnet
failsafe brakes as these products require an
adjustable current or voltage supply for optimum
release. These controls indicate when the output
channels are energized with LEDs
Suppression circuitry insures fast coil decay for
rapid cycle rates. Customer provided switching
is accomplished on the AC input to the control.
Specifications
Input
CBC-150-1:
120 VAC, 50/60 Hz, 1 phase, 200 VA max.
CBC-150-2:
220/240 VAC, 50/60 Hz, 1 phase, 200 VA max.
Output
CBC-150-1:
90 VDC full-wave rectified nominal,
Dual channel, 0.8A max. per channel.
CBC-150-2:
90 VDC half-wave rectified nominal,
Dual channel, 0.8A max. per channel.
Fusing
(external to control, supplied by customer)
CBC-150-1:
2 amp, 125 V fast-blo
CBC-150-2:
2 amp, 250 V fast-blo
Switching (
Supplied by customer on AC input )
1. Electromechanical (SPDT) (or Two SPST)
CBC-150-1:
Rated 120 VAC, 1 amp minimum
CBC-150-2:
Rated 240 VAC, 1 amp minimum
2. Solid State (maximum leakage current < 2ma)
CBC-150-1:
Rated 140 VAC, 2 amp minimum
CBC-150-2:
Rated 280 VAC, 2 amp minimum
Ambient Temperature
-20° to +122°F (-29° to 50°C)
Reorder Information
Model
Part Number
CBC-150-1
6004-448-001
CBC-150-2
6004-448-002
Conduit
5370-101-042
Cycle Rate
In most applications, the maximum cycle rate
is limited by the clutch and/or brake capability
rather than by the control. To determine specific
capabilities, consult the Application Engineering
section of Warner Electric's Catalogs. The
following table lists those clutch/brake models
whose maximum cycle rate may be limited by
this control.
Maximum Cycle Rate
Models Limited by Control
(cycles/min)
PB/PC-500
250
SF-500, EP-500, PB-650, EB-650
220
SF-650, EC-650, EM-210
175
PB/PC-825, EB-825
130
SF-825, EP-825, PC-1000, EB-1000
100
SF-825 brg., EC-825, EC-1000
95
SF-1000, EP-1000, PB/PC-1225
70
SF-1225, PB/PC-1525, EB-1225, AT-205
50
SF-1525, EP-1525, EC-1225
40
SF-1525HT
20
Failure to follow these
instructions may result in product damage,
equipment damage, and serious or fatal