t 0:
Keyboard Test: Tests the function of the front panel keys.
Press
to begin test. RUN: will be displayed. Press each front panel key except
to
test key. The display will indicate if the key is functional.
t 1:
Non-Volatile RAM Test: Tests CBC-1000 RAM.
Press
to begin test. The test will return PASS or FAIL. Press
to continue.
t 2:
Input Test: Tests whether CBC-1000 is accepting inputs.
Press
to begin test. Activate inputs to control.
If the input is received, a character will be displayed. “Ab” - Encoder
input, “1” - Start, “2” - Stop, “3” Continuous mode, “4” Reset. Press
to continue.
t 3:
Output Test: Used to determine whether CBC-1000 outputs are functional.
Press
to begin test. Press keys 1-6 on the front panel. The corresponding output will
turn on and latch. Use a VOM to check for a high level state on terminal strip of CBC-1000.
Press
to exit test.
t 4:
Display Test: Tests function of each LED on front panel.
Press
to begin test. Each digit of front panel display will automatically be turned on.
Check for faulty LEDs. Press
to continue.
t 5:
Program Memory Test: Tests program memory capability.
Press
to begin test. PASS or FAIL will be returned. Press
to continue.
t 6:
Date Code Test: Displays software date code.
Press
to display date code. Press
to exit. Continue.
t 7:
Serial Test: Tests connections with serial data interface module.
Press
to begin test. PASS or FAIL will be displayed. Press
to continue.
t 8:
Factory Default Settings: Returns CBC-1000 to factory settings.
Press
to return all program steps to factory default settings.