beautypg.com

Warner Electric CBC-100 User Manual

Cbc-100 series clutch/brake controls, Installation and operation manual

background image

Installation and Operation Manual

P-266

819-0472

CBC-100 Series Clutch/Brake Controls

Introduction

The Warner Electric CBC-100 series clutch/brake

controls are compact units designed for operation of

all Warner Electric 90 VDC clutches and brakes. They

should not, however, be used to directly power

Warner Electric permanent magnet failsafe brakes as

these products require an adjustable current or

voltage supply for optimum release.

The CBC-100 controls can be conveniently mounted

into any Warner Electric’s standard conduit box or

into any control panel. These controls are single

channel devices available in two models:

CBC-100-1

120 VAC input

CBC-100-2

220/240 VAC input

Internal circuitry provides suppression of transients

during decay of the magnetic field to assure fast cur-

rent decay for rapid cycle rates. Customer supplied

switching is accomplished on the AC input to the

control. The CBC-100 series controls are UL Listed

and CSA Certified.

Specifications

Input

CBC-100-1:120 VAC, 50/60 Hz, 1 phase, 100 VA max.
CBC-100-2: 220/240 VAC, 50/60 Hz, 1 phase, 100 VA max.

Output

CBC-100-1: 90 VDC full-wave rectified nominal, 0.8 amps max.
CBC-100-2: 90 VDC half-wave rectified nominal, 0.8 amps max.

Fusing

(external to control, supplied by customer)

CBC-100-1: 1 amp, 125 V fast-blo
CBC-100-2: 1 amp, 250 V fast-blo
Switching (

external to control, supplied by customer

on AC input)

1. Electromechanical (SPST)

CBC-100-1: Rated 120 VAC, 1 amp minimum
CBC-100-2: Rated 240 VAC, 1 amp minimum

2. Solid State (maximum leakage current < 2 ma)

CBC-100-1: Rated 140 VAC, 1 amp minimum
CBC-100-2: Rated 280 VAC, 1 amp minimum

Ambient Temperature

+32° to 122°F (0° to 50° C)

Reorder Information

Model

Part Number

CBC-100-1

6003-448-101

CBC-100-2

6003-448-103

Cycle Rate

In most applications, the maximum cycle rate is limited

by the clutch and/or brake capability rather than by the

control. To determine specific capabilities, consult the

Application Engineering section of Warner Electric

Catalogs, P-1234 and P-1264. The following table lists

those clutch/brake models which maximum cycle rate

may be limited by this control.

Maximum Cycle

Rate

Models Limited by Control

(cycles/min)

PB/PC-500

250

SF-500, EP-500, PB-650, EB-650

220

SF-650, EC-650, EM-210

175

PB/PC-825, EB-825

130

SF-825, EP-825, PC-1000, EB-1000

100

SF-825 brg., EC-825, EC-1000

95

SF-1000, EP-1000, PB/PC-1225

70

SF-1225, PB/PC-1525, EB-1225, AT-205

50

SF-1525, EP-1525, EC-1225

40

SF-1525HT

20