beautypg.com

Teledyne LeCroy QPHY-ENET User Manual

Page 54

background image

54

QPHY-ENET Operator’s Manual Rev G

Mode 1 and Mode 4 without Disturbing Signal

These tests are performed on a physical interface transmitting the mode 1 and mode 4 waveform. Test section G
is used to perform the peak voltage and template tests. When a disturbing signal is not used, the measurement
should be made with the device terminated by a 100 Ω resistive load. The test procedure is identical to

X

1000Base-T Peak Differential Voltage, Droop, Template - Mode 1 with Disturbing Signal

X

(page

X

48

X

) except

for not changing jumpers but changing a connection of SMA cable location in section G (

X

Figure 43

X

), when each

pair is measured, according to the table shown in

X

Table 6

X

. Mode 1 test uses Mode 1 signal and Mode 4 test uses

Mode 4 signal for the tests.

Table 6. Section G connector configuration and pair

Figure 43. Fixture setup for Mode 1 and Mode 4 test without Disturbing Signal

1.

On the oscilloscope’s Ethernet menu, Disturber present checkbox MUST be unchecked.

Figure 44. Menu setting for making the measurements without disturber present

Pair

CH2

CH3

A

J51

J30

B

J52

J31

C

J32

J53

D

J54

J33