O
PERATOR
’
S
M
ANUAL
FlexRay-TDP-OM-E Rev A
15
View Table Checkbox – Checking this box turns the Table ON. Un-
checking it turns the Table OFF.
Note: If the View Decode checkbox is not checked (i.e. decode is not ON), then the View
Table checkbox is grayed out. The Table cannot display unless decode is occurring.
When the Table is displayed, it appears similar to that shown to the
right. More details on the table can be found in the Protocol Table
section of this manual
Source Setup – Touch these selections to open a pop-up dialog box
which allows for selection of sources for the FlexRay data
This source can be either a Channel (C1 – C4), a Memory Trace (M1 –
M4), or a Math Function (F1 – F4).
A Channel would be used for a new, real-time acquisition. A Memory
would be used if you had saved data from a previous acquisition and
were recalling it to do further analysis. Reference the oscilloscope’s on-
line Help for information about how to Store and Recall Waveforms.
Protocol Selection – This pop-up dialog allows selection of a specific
serial protocol. If FlexRay is the only option installed on the
oscilloscope, it is the only choice; if additional options are installed they
appear on this dialog as well.
Action for Decoder Toolbar – Various buttons on this toolbar provide
context sensitive shortcuts for decoding.
• Search allows quick creation of a zoom trace and changes the
dialog box to the zoom/search dialog box. Acquire long records of
message data, and use Search to look through the record for a
particular message. Upon finding a message that meets the search
criteria, the complete message is displayed with the Zoom Trace.
Touch the arrow buttons to advance to the next message, or revert
to the previous message. Unsuccessful searches are noted in a text
line.
• Configure Table displays a pop-up dialog box specific to a
particular protocol. The pop-up dialog contains checkboxes for
various columns in the table. Check or uncheck the checkboxes to
display or not display that particular column in the table.
• Export Table exports the complete protocol table data to a user-
defined file. The output file name and directory can be selected by
the user using the controls to the right.