Adjustments spraying – Sunex Tools SX10A User Manual
Page 4
SX10A: Parts Breakdown & Operating Manual
4
rev. 04/29/06
FOR BEST PERFORMANCE,
PLEASE BE SURE TO DO THE FOLLOWING
BEFORE USING THIS TOOL
• Tighten the gun to the cup securely with the nut and fitting supplied.
• Be sure to have the proper air pressure at the gun to operate. Proper air pressure for this tool should not exceed 50 PSI.
• Adjust fluid control screw and spray width adjustment screw to your desired pattern before using on production.
• Clean all parts after use.
In normal use, the nozzle wings are
horizontal as shown here. This provides a
vertical fan-shaped pattern which gives
maximum, even material coverage as the
gun is moved back and forth parallel to the
surface being finished.
Spray pattern may be infinitely adjusted
from round to flat.
Set inlet pressure at no more than 50 PSI. For optimum
performance, some materials may spray better at PSI
ratings below 50 PSI. If unsure, always test at PSI ratings before
using on final production. Try spray. If it is too fine, decrease
the air pressure or open fluid control screw. If the spray is too
thick, close the fluid control screw. Regulate the pattern width
and repeat adjustment of spray as needed.
HVLP
ADjUSTMENTS
SPRAyING
Fluid control screw
Turn right to decrease flow, left to increase.
Spray width adjustment screw