11.3 Cleaning the Exterior
Wipe off dirt with a soft cloth.
Wipe the dust shield gently so that it does not bend.
Do not use strong compressed air on the actuator as this may force dust into the crevices.
Do not use petroleum-based solvents on plastic parts or painted surfaces.
If the unit is badly soiled, apply a neutral detergent or alcohol to a soft cloth and wipe lightly.
11.2 Visual Inspection of the Machine Exterior
Check the following when doing the visual inspection.
11. Maintenance
11.1 Maintenance Schedule
Perform maintenance work according to the schedule below.
Maintenance Checkpoints
Note 1: The above schedule assumes running time is 8 hours per day. When running time is high such as
continuous day and night operation, shorten the maintenance intervals as required.
Note 2: The end cover supports the ball screw so please do not remove it. Do not remove the encoder cover
as this contains precision equipment
Visual
inspection
Check for loose
dust shield
Check interior
Lubrication
Start of operation
m
After 1 month of operation
m
m
After 6 months of operation
m
m
m
After 1 year of operation
m
m
m
m
Seminually thereafter
m
m
Annually thereafter
m
m
m
m
Body
Loose mounting bolts?
Cables
Damage to cables or
connection to connector box?
General
Unusual noise or vibrations?