NOTE: See the instruction sheet included with the mixing valve to adjust the maximum temperature of the mixing valve greater than
120

o

F.

Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a setting of 140

o

F (60

o

C). Water temperature

over 125

o

F can instantly cause severe burns, or death, from scalds. Children, disabled, and elderly are at the highest risk of being

scalded. See instruction manual before setting temperature at appliance. Feel water before bathing or showering!

MIXING VALVE MAINTENANCE AND SERVICE

It is recommended to check the mixing valve annually to ensure proper system capabilities. More frequent checks are
recommended in adverse water conditions.

When checking the mixed water supply temperature, use the same faucet used in the initial installation temperature
adjustment.

There may be some variation in the water temperature from the mixing valve due to seasonal temperature variations in the
cold water supply.

If the water supply is of poor quality, the internal components may jam, requiring an additional filter or strainer to be fitted to
the system. Contact a plumbing professional for appropriate materials and installation.

O. VERSA-FLAME DHW PERFORMANCE

Figure 8

– DHW Pack Performance on 130K BTU Models