TROUBLESHOOTING GUIDE (Cont.)

(Continued On Next Page)

General Problem

Procedure

Solution

LOSS OF FEEDBACK

Fault (LF) (Cont.)

Invalid Speed

Request Fault (In)

3. Defective Fiber Optic Re-

ceiver Module, cable or

transmitter

4. Defective volume booster

regulator or seized rotator

5. Current to Pressure Trans-

ducer disconnected or

defective

6. Defective Control Card

1. Speed setpoint set too high

on Speed Select Thumb-

wheel Switch (local mode)

or from remote analog input

(remote mode)

2. Defective Atomizer Card

(local mode)

3. Defective analog input

source (remote mode)

3. Check the red speed feedback LED located

on the Fiber Optic Receiver Module for the

channel in question. The LED should come

on if the turbine rotates when enabled.

If the LED does NOT come ON, disconnect

the fiber optic cable, enable the rotator and

look for a red light from the cable while the

rotator is spinning. If no light can be ob-

served, then replace the fiber optic cable.

If light is observed, then replace the fiber

optic receiver.

If the fiber optic cable is replaced and the

problem still exists, then replace the fiber

optic transmitter located on the rotator.

Hint: A fiber optic cable from an operational

rotator can be temporarily switched to a

different receiver input to help verify the

above.

4. Check Current to Pressure Transducer output

pressure. If it is increasing and rotator does

not spin, check volume booster regulator

and rotator for cause.

5. Verify electrical and pneumatic connections

to Current to Pressure Transducer for corre-

sponding rotator. If all items above are OK

and there is no output from the transducer,

then replace it.

6. If all items above are OK, replace the control

card.

1. Lower speed setpoint command.

2. Replace Atomizer Card.

3. Repair or replace input source.