beautypg.com

Ransburg PulseTrack2 A11515-XXXXX User Manual

Page 43

background image

Overspeed (oS) Fault:

1. The braking air solenoid is not functioning

properly.

2. The brake air line has lost connection to the

rotator.

3. The brake air valve is defective.

4. The current to pressure transducer is not func-

tioning properly.

Loss of Feedback (LF) Fault:

1. Supply air to control panel or rotator turned off.

2. Pneumatic transducer output (CL1 - CL6) dis-

connected.

3. Fiber Optic Cable is damaged or not connected.

4. Faulty air volume booster.

5. Transducer electrical input disconnected or

faulty transducer.

6. Faulty Control Card.

7. Faulty Fiber Optic Receiver module.

8. The rotator has seized and will not spin.

Invalid Speed Request (In) Fault:

1. Speed setpoint set too high.

2. Defective atomizer card (local mode).

3. Defective analog input source (remote mode).

No Connection (nc) Fault

(Temperature/Humidity Card):

1. Loose or defective cable connection between

control panel and Temperature/Humidity Probe.

A speed control problem may be associated with

any of the components that make up the entire

system. First, try to isolate generally, where in

the system the problem lies. If the same problem

is occurring on more than one rotator, inspect

those system elements that are common to all

the problem rotators. This includes the air supply

pressure to the control panel as well as the re-

motely mounted air piloted regulators. This also

includes the Control Card, 24VDC power supply,

front panel switches, fuses, AC line filter and any

wiring associated with them.

If the problem occurs on one rotator but not oth-

ers, inspect those system elements that are spe-

cific to each rotator. These include the Atomizer

Cards, current to pressure transducers, pressure

switches, Fiber Optic Receiver Modules, brake

valves, brake solenoids and any wiring or tubing

associated with them.