Table 4 - analog output settings, Table 5 - electrical i/o – Ransburg PulseTrack2 A11515-XXXXX User Manual
Page 26

Master Overspeed Output
A 24VDC discreet output exists at breakout
terminal J3-C23 to indicate when an overspeed
fault occurs on any rotator. Using this output in
conjunction with the individual rotator fault output it
is possible to remotely determine on which rotator
the overspeed fault occurred. Maximum output
current from this output is 250mA.
Master Fault Output
A 24VDC master fault indicator exists on the front of
the control panel that is lit any time a fault occurs.
This active high output is also available remotely
at breakout terminal J3-C24. Thus, this discreet
output puts out 24VDC when a fault occurs. Max-
imum output current from this output is 250mA.
Brake Outputs (Optional, Bells Only)
24VDC brake outputs are located at breakout ter-
minals J3-C25 through J3-C30. For bell systems
configured with the brake option, these outputs
send 24VDC to the brake solenoids when bell
speed is decreased and/or disabled.
1
E6 on Pins 1 & 2
OFF
E6 on Pins 2 & 3
ON
2
E5 on Pins 1 & 2
OFF
E5 on Pins 2 & 3
ON
3
E4 on Pins 1 & 2
OFF
E4 on Pins 2 & 3
ON
4
E3 on Pins 1 & 2
OFF
E3 on Pins 2 & 3
ON
5
E2 on Pins 1 & 2
OFF
E2 on Pins 2 & 3
ON
6
E1 on Pins 1 & 2
OFF
E1 on Pins 2 & 3
ON
TABLE 4 - ANALOG OUTPUT SETTINGS
Rotator
0-10VDC Setting
4-20mA Setting
Jumper Setting
Dipswitch 7
Jumper Setting
Dipswitch 7
Rotator 1 Analog Speed Setpoint Input
Rotator 2 Analog Speed Setpoint Input
Rotator 3 Analog Speed Setpoint Input
Rotator 4 Analog Speed Setpoint Input
Rotator 5 Analog Speed Setpoint Input
Rotator 6 Analog Speed Setpoint Input
Rotator 1 Enable Input
Rotator 2 Enable Input
Rotator 3 Enable Input
Rotator 4 Enable Input
TABLE 5 - ELECTRICAL I/O
J2-A1
J2-A2
J2-A3
J2-A4
J2-A5
J2-A6
J3-C15
J3-C16
J3-C17
J3-C18
Breakout Terminal
Description
4-20mA/0-10VDC
4-20mA/0-10VDC
4-20mA/0-10VDC
4-20mA/0-10VDC
4-20mA/0-10VDC
4-20mA/0-10VDC
Active Low (Maintained)
Active Low (Maintained)
Active Low (Maintained)
Active Low (Maintained)
Type