MAINTENANCE

GENERAL

Developing a good preventive maintenance (PM)

program is key to keeping any system operating

properly, the frequency of which is determined by

each individual installation. Contact your Ransburg

representative or the Ransburg Service depart-

ment for guidelines or assistance in establishing

a preventative maintenance program.

For maintenance of system components other

than the PulseTrack 2, refer to the appropriate

manual or contact your Ransburg repre-sentative

or Ransburg Customer Service.

SCHEDULED

MAINTENANCE

There is no maintenance schedule for the control

panel other than good housekeeping practices.

These include:

1. Keeping the door closed at all times to maintain

the dust-tight environment that is preferable for

the electronic circuit boards and wiring.

2. Plug all unused access holes in the cabinet to

keep contaminants out.

3. The cabinet exterior may be cleaned with a

clean, dry, lint-free cloth. If necessary, isopropyl

alcohol or other mild cleaning solutions can be

used.

4. Window cleaner or a mild solvent may be used

to clean the glass window in the small swing-out

door.

>

Field repair and troubleshooting of the

PulseTrack 2 Control Panel may require

exposure to potentials that can cause

SERIOUS BODILY INJURY or DEATH if

proper procedures are not followed. For

this reason, troubleshooting and field repair

should only be accomplished with specif-

ic test equipment by qualified electronics

technicians or authorized Ransburg repre-

sentatives.

W A R N I N G

!

Fuses (F1, F2 - reference
Figure 4)

1. Turn off AC Power to the control panel at the

Fused Disconnect.

2. Open the cabinet door and locate TB3 in the

upper left corner of the cabinet.

3. Pull up on the center portion of terminal block

TB3-F1 or TB3-F2 to access the fuse.

4. Push the fuse out with a small screwdriver or

similar tool and replace with a new one.

5. Push center portion of terminal block back in,

secure cabinet door and restore AC power.

Atomizer or Temperature/
Humidity Card

1. Turn off AC Power to the control panel at the

Fused Disconnect.

2. Open the cabinet door and disconnect the rib-

bon cable from the rear of the card to be replaced.

REPLACEMENT

PROCEDURES