Figure 10: Control Card

DIP SWITCH SETTINGS

Control Card

There is an 8 position dip switch SW1 located

near the bottom of the control card (see Figure

10). Positions 2, 3, 4 and 5 presently have no

function and should be set to the OFF position

(factory setting). The remaining dip switches are

described below and summarized in Table 6. To

change the position of a dip switch, perform the

following:

1. Turn AC power off and access the interior of

the cabinet.

2. Change the desired dip switch setting.

3. Secure the cabinet door and turn AC power

back on.

> The AC power must be cycled for the

new dip switch setting to be recognized.

NOTE

Dip Switch SW1-1

This dip switch can be used with bell systems

configured for optional brake control. When this

dip switch is on, brake air is applied to assist in

bringing the bell to a stop when speed control is

turned off, as well as when decreases in operating

speed are made. When this switch is off (factory

setting), brake air is only used when decreases

in operating speed are made and is

NOT applied

when speed control is turned off.

Dip Switch SW1-6

This dip switch is used to set the mode of the an-

alog speed setpoint inputs. When this dip switch

is off, (factory setting) all analog speed setpoint

inputs are set for 0-10VDC input control. When

this dip switch is on, all analog speed setpoint

inputs are set for 4-20mA input control.