Dip switch settings, Control card – Ransburg PulseTrack2 A11515-XXXXX User Manual
Page 28
Figure 10: Control Card
DIP SWITCH SETTINGS
Control Card
There is an 8 position dip switch SW1 located
near the bottom of the control card (see Figure
10). Positions 2, 3, 4 and 5 presently have no
function and should be set to the OFF position
(factory setting). The remaining dip switches are
described below and summarized in Table 6. To
change the position of a dip switch, perform the
following:
1. Turn AC power off and access the interior of
the cabinet.
2. Change the desired dip switch setting.
3. Secure the cabinet door and turn AC power
back on.
> The AC power must be cycled for the
new dip switch setting to be recognized.
NOTE
Dip Switch SW1-1
This dip switch can be used with bell systems
configured for optional brake control. When this
dip switch is on, brake air is applied to assist in
bringing the bell to a stop when speed control is
turned off, as well as when decreases in operating
speed are made. When this switch is off (factory
setting), brake air is only used when decreases
in operating speed are made and is
NOT applied
when speed control is turned off.
Dip Switch SW1-6
This dip switch is used to set the mode of the an-
alog speed setpoint inputs. When this dip switch
is off, (factory setting) all analog speed setpoint
inputs are set for 0-10VDC input control. When
this dip switch is on, all analog speed setpoint
inputs are set for 4-20mA input control.