TO ENABLE SPEED

CONTROL

To enable speed control, first make sure the Pulse-

Track 2 is installed as detailed in the "Installation"

section of this manual.

Local Mode Operation

1. Turn the front panel Power ON/OFF switch

to the ON position.

2. Ensure the local/remote switch on the Atomiz-

er Card is in the local position.

3. Turn the front panel Master Control Switch to

the RUN position or activate the electrical master

enable input (see "Electrical I/O" in the "Installation"

section of this manual).

4. Activate the enable input for the given rotator

either by supplying air to the corresponding EN

input on the right side of the control panel or by

activating the corresponding electrical enable input

(see "Enable Inputs" in the "Installation" section

of this manual).

5. Using the Speed Select Thumbwheel Switch on

the Atomizer Card, set the desired speed setting

for the corresponding rotator and press the Speed

Enter Button.

6. Move the Atomizer Card Enable/Disable/Re-

set Switch to the enable position. Speed control

should begin on the rotator corresponding to the

selected atomizer card.

Remote Mode Operation

1. Set Dip Switch SW1-6 on the Control Card for

the desired mode of operation. For a 0-10VDC

input signal set SW1-6 to the OFF position. For a

4-20mA input signal set SW1-6 to the ON position

(see "Dip Switch Settings" in the "Installation "

section of this manual).

2. Turn the front panel Power ON/OFF switch to

the ON position.

3. Move the local/remote switch on the Atomizer

Card to the remote position.

4. Turn the front panel Master Control Switch to

the RUN position or activate the electrical master

enable input (see "Electrical I/O" in the "Iinstalla-

tion" section of this manual).

5. Activate the enable input for the given rotator

either by supplying air to the corresponding EN

input on the right side of the control panel or by

activating the corresponding electrical enable input

(see "Enable Inputs" in the "Installation" section

of this manual).

5. Supply a 0-10VDC or 4-20mADC input sig-

nal to the electrical I/O breakout terminal J2-A1

through J2-A6 corresponding to the given rotator

(see "Table 5" in the "Installation" section of this

manual).

6. Move the Atomizer Card Enable/Disable/Re-

set Switch to the enable position. Speed control

should begin on the rotator corresponding to the

selected atomizer card.

TO DISABLE SPEED

CONTROL

Speed control can be disabled using any of the

following methods:

1. Move the Atomizer Card Enable/Disable/Reset

Switch to the disable position. This will disable

speed control to the rotator corresponding to the

given Atomizer Card.

2. Deactivate the enable input for the given rotator

either by removing air from the corresponding EN

input on the right side of the control panel or by

deactivating the corresponding electrical enable

input (see "Enable Inputs" in the "Installation "

section of this manual). This will disable speed

control to the corresponding rotator.