Rotary dip switch, Table 7 - atomizer card sw2 dip switch settings – Ransburg PulseTrack2 A11515-XXXXX User Manual

Page 30

background image

>The AC power must be cycled for the

new dip switch setting to be recognized.

NOTE

Temperature/Humidity Card

There is also a 4 position dip switch SW2 located

near the bottom of each temperature/humidity

card. These dip switches should always be set

to the OFF position.

Rotary DIP Switch

There is a rotary DIP switch SW1 located on each

Atomizer and Temperature/Humidity Card (see

Figure 11). The setting of this switch must match

the slot number the card is occupying as listed on

the label inside the front panel door (reference

Figure 18).

Figure 11: Atomizer Card Dip Switch

6" Conical Disk
6" UniDisk
8" UniDisk & 9" Conical Disk
10" UniDisk
12" UniDisk & 12" Conical Disk
Standard Aerobell

Aerobell 33 (30 & 57mm)

Rotator Type

SW2-2

SW-2-1

OFF

ON
ON
ON
ON

OFF

OFF

TABLE 7 - ATOMIZER CARD SW2 DIP SWITCH SETTINGS

OFF
OFF
OFF
OFF

ON

OFF

ON

SW2-3

OFF
OFF
OFF

ON

OFF

ON

OFF

OFF
OFF

ON

OFF
OFF

ON

ON

Maximum

Speed

40,000 rpm
27,000 rpm
23,000 rpm
15,000 rpm
15,000 rpm
60,000 rpm

50,000 rpm

SW2-4

Ordering

Configuration

A11515-XXX1X
A11515-XXX4X
A11515-XXX5X
A11515-XXX6X
A11515-XXX7X
A11515-XXX2X
A11515-XXX8X
A11515-XXX3X
A11515-XXX9X