Control card (refer to figure 19) – Ransburg PulseTrack2 A11515-XXXXX User Manual
Page 39
Figure 15: AC Line Filter (Top View)
24VDC Power Supply (refer to Fig-
ures 6, 18, and 19)
1. Turn off AC Power to the control panel at the
Fused Disconnect.
2. Open the cabinet door and pull up on the center
portion of the TB3-F1 and TB3-F2 terminal blocks
to open the AC line fuses.
3. Using a small blade screwdriver, disconnect
the wires from TB1 and TB2 of the 24VDC supply.
4. Using a screwdriver, pull back the retaining
clamp at the bottom of the power supply on the
TB1 side while
at the same time lifting up
on that side of the supply.
5. Remove the power supply from the unit and
replace with a new one, reconnecting the wires
as follows:
Color
From
TB3-Ground
SW1-B3
SW1-A4
SW1-X1
TB4-1C
SW1-X2
TB4-1D
Wire
ID
Green/Yellow
Light Blue
Black
Dark Blue
Dark Blue
Dark Blue
Dark Blue
GND
6
7
24
24
COM
COM
To
TB1-1
TB1-2
TB1-3
TB2-1
TB2-2
TB2-3
TB2-4
6. Push fuse blocks back in, secure cabinet door
and restore AC power.
Control Card (refer to Figure 19)
1. Turn off AC Power to the control panel at the
Fused Disconnect and open the cabinet door.
2. Remove the ribbon cable from the Control Card.
3. Depress the two control card release pins.
4. Pull the Control Card out of its mounting socket
and replace.
5. Install new Control Card in reverse order of
disassembly.
6. Ensure the new Control Card DIP switch SW1
settings are correct (reference Table 6).
7. Secure cabinet door and restore AC power.