beautypg.com

Introduction, Specifications, General information – Ransburg Test Stand RMA-303, EVOLVER, EVOLVER NE User Manual

Page 8: Electrical / physical, N o t e

background image

LN-9259-07.1

INTRODUCTION

SPECIFICATIONS

Electrical / Physical

GENERAL INFORMATION

The Ransburg Applicator Performance Test Stand

was developed to assist in determining the appli-

cator’s level of performance in an off-line condi-

tion. (Ensuring the applicator functions properly

after any maintenance has been performed to it

and reduces the costs associated with verifying

performance during production.) With line speeds

critical to the through-put of a facility, every uptime

minute counts to underwrite profitability. This

Test Stand device helps to ensure the applicator

performs correctly when it is put into service.

This Test Stand will verify performance of single

or dual fluid applicators, bearing air, shaping air,

brake air, turbine drive air, and fiber optic func-

tionality. As well, it checks kV and µA electrical

performance of the applicator.

The Test Stand was developed with the user and

the safety of the user in mind. The user must

become familiar with the overall function and

operation of the unit.

Air Requirements:

1-inch NPT(F) Inlet

3/4-inch ID Air Line to Stand

100 psi (6.4 bar) minimum

30

SCFM

0.3 to 0.6 Micron Filtration

Dimensions

Height:

67-inch (1702cm)

Width:

30-inch (762cm)

Length:

48-inch (1219cm)

Fluids:

Use distilled or deionized

water only for testing.

Maximum Fluid

Pressure:

80 psi (5.2 bar)

N O T E

> For all test station toggle switches, with the

switch lever in the “UP” position, the valve it

describes is “ON” or “actuated.”

Test Stations - Introduction

5