• Mounting the compressor to a stable, rigid
operating surface and using shock mounts will
reduce noise and vibration.
• Kasco Marine includes with no cabinet systems a
simple, durable bracket accessory that will allow
you to easily mount the compressor to a wall, floor
or bench.
After the proper location has been determined, use the
following diagram to complete the installation.
PTFE
Thread
Sealant
Outlet
Connect toSureSink
or Non-Weighted
Tubing.
Remove plug using
1/4” hex key
RA(H)1-NC Shown
Outlet
Inlet
PTFE
Thread
Sealant
Connect to
SureSink
or Non-
Weighted
Tubing.
Remove
outlet plug
using 1/4”
hex key
RA(H)3-NC Shown
120V compressors are supplied with a NEMA 5-15
Plug which can be plugged into a 120V receptacle.
240V compressors are supplied with flying leads. The
leads can be hard-wired into 240V service or a plug
can be installed on the cord if plugging into a recep-
tacle.
Kasco Marine highly recommends that the site service
providing the system have a human-rated Ground
Fault Circuit Interrupter outlet (120V) or human-rated
Ground Fault breaker (240V) for your protection.
Contact a licensed electrician to bring 120 or 240
volt (depending on which model is purchased), single
phase electrical supply to the compressor location and
to install appropriate human-rated ground fault protec-
tion.