2

Important Safety Instructions

CAUTION

• Caution should be used when dealing with any

electrical equipment with moving parts.

• Extreme caution should be used around water,

especially cold water, such as in Spring, Fall,

and Winter, which poses a hazard in and of

itself.

• Running the system in freezing conditions may

create open areas of water in the ice at the

diffuser locations and also thin ice around the

area.

• Check your local laws and ordinances as some

areas require warning signs to be posted. The

owner will assume all risks with operating the

Robust-Aire System during winter months.

• Do not use waders in deep ponds/lakes or

ponds/lakes with drop-offs, drastic slopes, or

soft bottom material.

• Do not use boats that tip easily for installation,

such as a canoe, and follow all boating safety

rules and regulations, including wearing a PFD.

(Personal Flotation Device)

• Means for disconnection must be incorporated

in the fixed wiring in accordance with local and

national wiring rules.

• Consult a qualified electrician for electrical

installation.

Unit Specs

Model* Voltage # diffusers

# compressors

Total amps

RA1

120

1

1

3.6

RAH1

240

1

1

1.8

RA2

120

2

1

5.4

RAH2

240

2

1

3.0

RA3

120

3

1

5.4

RAH3

240

3

1

3.0

RA4

120

4

2

10.8

RAH4

240

4

2

6.0

RA5

120

5

2

10.8

RAH5

240

5

2

6.0

RA6

120

6

2

10.8

RAH6

240

6

2

6.0

*you may have a suffix at the end of your model. “NC”

stands for “no cabinet”. “PM” stands for “post-mount cabi-

net”. No suffix denotes the standard base-mount cabinet.

The specs should be used by your qualified electrician

to ensure properly sized circuits are installed. For all

RAH systems and systems RA1 - RA3, a dedicated 15

amp circuit is sufficient to supply power to the system.

For RA4 – RA6 systems, a dedicated 20 amp circuit is

recommended. For RA(H)4 – RA(H)6 systems (two

compressors and two fans), it may be useful to have

two dedicated 15 amps circuits available. This will

allow for one compressor/fan combination to continue

operating if the other compressor were to fail, be down

temporarily for maintenance or to allow sets to be run

intermittently during start-up to prevent a turn-over

(see start-up procedure for more info). Always consult
with a qualified electrician.

ROBUST-AIRE

®

DIFFUSER ASSEMBLY

Parts Included

• (1) Robust-Aire

®

Diffuser Assembly

• (1) Vent Plug

• (1) 3/8” Tubing Clamp

• (1) 5/8” Tubing Clamp

• (1) ½” NPT x 3/8” Barb Elbow

• (1) ½” NPT x 5/8” Barb Elbow

• (1) 3/8” Tubing Strain Relief

• (1) 5/8” Tubing Strain Relief

• (1) ¼”-20 x 1-3/8” Lg Hex Head Capscrew

• (2) ¼” Flat Washer

• (1) ¼”-20 Lock Nut

*Not all fittings will be used. Use 3/8” fittings with

3/8” SureSink ™ Aeration Tubing and 5/8” fittings

with 5/8” SureSink ™ Aeration Tubing.

Installation Tools & Materials

• 7/8” Open End Wrench or Pliers

• 20-30 lbs (.25-.375 cu.ft.) of pea gravel

• Length of ¼” – 3/8” nylon rope (or equivalent).

Rope length to be at least twice the water depth

• 7/16” socket wrench

• 7/16” box or open end wrench

• 5/16” Socket wrench or screwdriver

• PTFE thread sealant (teflon tape)