Warranty

Warranty Period: 2 year

Kasco

®

Marine, Inc. warrants this Robust-Aire

®

System to be free from defects in material or work-

manship under normal use and service. The Kasco

Marine, Inc. obligation under this warranty is limited

to replacing or repairing free of charge any defective

part within the warranty period. Customer shall pay

shipping charges for returning the unit to Kasco or an

Authorized Repair Center.

THIS WARRANTY IS IN LIEU OF ANY OTHER

WARRANTIES, EXPRESSED OR IMPLIED, AND

ANY OTHER OBLIGATION OR LIABILITY

WHATEVER ON THE PART OF KASCO MARINE,

INC. AND IN NO EVENT SHALL KASCO MA-

RINE, INC. BE LIABLE FOR ANY SPECIAL OR

CONSEQUENTIAL DAMAGES.

Warranty is void if:

• The System is not maintained properly according

to the Maintenance Recommendations supplied in

this Owners Manual.

• The System is damaged by unauthorized tamper-

ing.

Warranty Claim Procedure:

The best method for establishing warranty period is by

the original receipt. Also, register the System online

at: www.kascomarine.com.

Once the warranty coverage has been established, the

unit may be sent to any Kasco Authorized Repair Cen-

ter for evaluation and repair. Please call Kasco Ma-

rine at 715-262-4488 prior to shipping to receive any

updated information and/or Repair Form, then ship to:

Kasco Marine, Inc.

800 Deere Rd.

Prescott, WI 54021

Attn: Repairs

Or call Kasco Marine at 715-262-4488 to locate your

nearest Authorized Repair Center. You can also email

Kasco at [email protected].

Please include the Repair Form received from Kasco

Marine or your local distributor with the shipment. If

no Repair Form is available, include your name and

physical address for return delivery of the repaired

Kasco recommends checking the filter every month.

Clean or replace as necessary. This one procedure

will help assure the product’s performance and service

life. Failure to maintain clean air filter elements will

lead to clogging which will cause excessive heat and

premature failure of the compressor.

• Remove filter cover

• Remove felt and replace filter element

• Replacement filter elements are readily available.

Please contact your local Kasco distributor and

ask for the Replacement Air Filter Element Model

771010 (felt, used with plastic filter assembly)

or Model 771014 (Paper, used with metal filter

assembly).

• Reinstall filter element and cover.

Troubleshooting

Here are some helpful troubleshooting tips. If a

problem occurs, please double check the assembly and

installation instructions. Please contact Kasco or your

distributor if problems persist after reviewing these

instructions.

“Compressor and fan are not running.”

Check to make sure the power cord is connected.

Check if the user supplied GFCI circuit is tripped and

if it is, push the reset button.

“The fan is running but the compressor is not”

Check the compressor and capacitor wiring. If no

damage is seen, a bad capacitor or compressor may be

the issue.

“The compressor and fan are running, but there are

no bubbles coming out of any of our diffusers”

Check for any leaks in the line connections and in the

cabinet. Retighten any loose connections. The com-

pressor air filter may need to be cleaned or replaced.

“The compressor and fan are running. There are

bubbles coming out of some diffusers, but not all of

them.”

The valves in the cabinet may need to be balanced cor-

rectly. There may be a clog on a diffuser that needs to

be removed. The compressor may be faulty and need

a rebuild kit.

“The compressor stops and restarts”

Possibly a heat issue. Check to see if the fan is work-

ing properly.