Kasco Marine Robust-Aire User Manual
Page 10

10
Warranty
Warranty Period: 2 year
Kasco
®
Marine, Inc. warrants this Robust-Aire
®
System to be free from defects in material or work-
manship under normal use and service. The Kasco
Marine, Inc. obligation under this warranty is limited
to replacing or repairing free of charge any defective
part within the warranty period. Customer shall pay
shipping charges for returning the unit to Kasco or an
Authorized Repair Center.
THIS WARRANTY IS IN LIEU OF ANY OTHER
WARRANTIES, EXPRESSED OR IMPLIED, AND
ANY OTHER OBLIGATION OR LIABILITY
WHATEVER ON THE PART OF KASCO MARINE,
INC. AND IN NO EVENT SHALL KASCO MA-
RINE, INC. BE LIABLE FOR ANY SPECIAL OR
CONSEQUENTIAL DAMAGES.
Warranty is void if:
• The System is not maintained properly according
to the Maintenance Recommendations supplied in
this Owners Manual.
• The System is damaged by unauthorized tamper-
ing.
Warranty Claim Procedure:
The best method for establishing warranty period is by
the original receipt. Also, register the System online
at: www.kascomarine.com.
Once the warranty coverage has been established, the
unit may be sent to any Kasco Authorized Repair Cen-
ter for evaluation and repair. Please call Kasco Ma-
rine at 715-262-4488 prior to shipping to receive any
updated information and/or Repair Form, then ship to:
Kasco Marine, Inc.
800 Deere Rd.
Prescott, WI 54021
Attn: Repairs
Or call Kasco Marine at 715-262-4488 to locate your
nearest Authorized Repair Center. You can also email
Kasco at [email protected].
Please include the Repair Form received from Kasco
Marine or your local distributor with the shipment. If
no Repair Form is available, include your name and
physical address for return delivery of the repaired
Kasco recommends checking the filter every month.
Clean or replace as necessary. This one procedure
will help assure the product’s performance and service
life. Failure to maintain clean air filter elements will
lead to clogging which will cause excessive heat and
premature failure of the compressor.
• Remove filter cover
• Remove felt and replace filter element
• Replacement filter elements are readily available.
Please contact your local Kasco distributor and
ask for the Replacement Air Filter Element Model
771010 (felt, used with plastic filter assembly)
or Model 771014 (Paper, used with metal filter
assembly).
• Reinstall filter element and cover.
Troubleshooting
Here are some helpful troubleshooting tips. If a
problem occurs, please double check the assembly and
installation instructions. Please contact Kasco or your
distributor if problems persist after reviewing these
instructions.
“Compressor and fan are not running.”
Check to make sure the power cord is connected.
Check if the user supplied GFCI circuit is tripped and
if it is, push the reset button.
“The fan is running but the compressor is not”
Check the compressor and capacitor wiring. If no
damage is seen, a bad capacitor or compressor may be
the issue.
“The compressor and fan are running, but there are
no bubbles coming out of any of our diffusers”
Check for any leaks in the line connections and in the
cabinet. Retighten any loose connections. The com-
pressor air filter may need to be cleaned or replaced.
“The compressor and fan are running. There are
bubbles coming out of some diffusers, but not all of
them.”
The valves in the cabinet may need to be balanced cor-
rectly. There may be a clog on a diffuser that needs to
be removed. The compressor may be faulty and need
a rebuild kit.
“The compressor stops and restarts”
Possibly a heat issue. Check to see if the fan is work-
ing properly.