beautypg.com

Darex XT-3000A User Manual

Page 47

background image

45

To sharpen the tool, determine which angle the

tool will be sharpened at. To adjust the X-Y table,

loosen the Pivot Lock Knob and swing the table to

that angle. Tighten the Pivot Lock Knob.

Remove the

Countersink

Attachment from

the top of the

machine and

place it on the X-Y

Table. Again,

rotate the

Docking Lever

clockwise to secure the fixture. Turn the machine

ON.

Using both the X and Y axis feed knobs, carefully

position the cutter into the grinding wheel.

Once the

tool touches

the grind

wheel, begin

to rotate the

spindle in a

clockwise

direction

slowly

feeding the

cutter into the wheel. Once the desired amount is

ground off, continue rotating 1 or 2 more

revolutions to “spark out” the cutter. While still

rotating the spindle, use one of the feed axis

knobs to position the cutter safely away from the

grinding wheel. Loosen the Docking Lever and

return the Countersink Assembly to the top of the

XT-3000 to remove the cutter. The sharpening is

now complete.

Y-Axis Knob

X-Axis Knob

Pivot Lock Knob

This manual is related to the following products: