Trouble shooting xt-3000 drill sharpening – Darex XT-3000A User Manual
Page 26
24
Symptom
Using ON/OFF switch does not work
Machine won’t power up
Cause
•
No power at outlet
•
Make sure power cord is plugged in to
machine and outlet
•
Release e-stop (230v machine only)
•
E-stop nut is loose and stuck down in the
off position (230v machine only)
•
On/off switch needs to be replaced
•
Wiring lead disconnected
Symptom
Tip of drills burn or discolor
Cause
•
Wheel needs to be cleaned
•
Material take off too aggressive
•
Wheel needs to be replaced
•
Grinding wheel obstructed and can’t rotate
•
Grinding motor bad
Symptom
Unable to secure drill in or release drill
from chuck
Cause
•
Tapered shank drill
•
The drill may have a slight taper to the
body
•
Shank of drill larger than body
•
Drill has multiple diameters that are
interfering with jaws
•
Incorrect drill diameter for that particular
chuck
•
Drill flutes are damaged or have burrs
•
Chuck needs to be cleaned
Symptom
Drill incorrectly split
Cause
•
Check settings on the split point fixture
•
Did not align correctly
•
Point Split Tube calibration is off
Symptom
Material take off varies
Cause
•
Wheel not secure to motor hub
•
Wheel calibration is off after new wheel
change
•
Cam dog not properly seated in alignment
slot during alignment set up
•
Drill is pushing back in the chuck during
grinding
•
Operator is not sparking drill out
Symptom
No material take off during grinding
Cause
•
Drill loose in chuck
•
Drill tip not touching the pusher shaft cap
during alignment process
Symptom
Length of time drill is in the grind becomes
excessive
Cause
•
Material take off too excessive
•
Grinding wheel needs to be cleaned
•
Grinding wheel needs to be replaced
Symptom
Lip height concentricity is out of tolerance
Cause
•
Material take off too excessive
•
Chuck needs to be cleaned
•
Sharpening tube needs to be cleaned
•
Chuck is worn out and needs to be
replaced
•
Sharpening tube is worn and needs to be
replaced
•
Wheel is not running true
Trouble Shooting XT-3000 Drill Sharpening