Plc / axis unit bank data – FEC AFC1100 User Manual
Page 14

)(& ,QF
SV ERROR 2
DATA 7
SV ERROR 1
DATA 6
Outputs a detailed code when a SV AMP
ERR is output. Error code is output in three
bits. (See Section 4.7.3 ).
SV ERROR 0
DATA 5
Outputs when a servo abnormality occurs,
see SV ERR 0~2 codes below.
SV AMP ERR
DATA 4
Outputs when a tool related abnormality
occurs.
TOOL ERR
DATA 3
Outputs when an abnormal condition occurs
in the encoder.
ENC ERR
DATA 2
Outputs when an abnormal condition occurs
in the parameter setting.
PSET ERR.
DATA 1
Outputs when an abnormal condition occurs
during the SELF CHECK (CAL and Zero).
ZERO CAL
ERR
DATA 0
ON
ON
4
not used
DATA 7
not used
DATA 6
Output when Fastening resulted in a 2nd
Torque Rate Low Reject.
2ND RATE
LOW REJECT
DATA 5
Output when Fastening resulted in a 2nd
Torque Rate High Reject.
2ND RATE
HIGH REJECT
DATA 4
Output when Fastening resulted in a 1st
Torque Rate Low Reject.
1ST RATE
LOW REJECT
DATA 3
Output when Fastening resulted in a 1st
Torque Rate High Reject.
1ST RATE
HIGH REJECT
DATA 2
Output when Fastening resulted in an Angle
Low Reject.
ANGLE LOW
REJECT
DATA 1
Output when Fastening resulted in an Angle
High Reject.
ANGLE HIGH
REJECT
DATA 0
OFF
ON
3
DESCRIPTION
NAME OF
SIGNAL
BANK DATA
PINS 25 ~ 18
0
PIN 13
1
PIN12
BANK
#
PLC / AXIS UNIT BANK DATA
BANK
SELECT
INPUT
Chapter 4: System Setup and Wiring (Rev. 8/98)
Page 4-14