Teledyne 5000B - Near Infrared Photometer User Manual
Page 102
![background image](/manuals/345675/102/background.png)
A-2
Appendix
Models 5000B
Teledyne Analytical Instruments
Typical Analytical Performance Specifications:
(
will vary per application
)
Accuracy:
±2% of full scale or better, application dependent
Noise:
Less than ±1%
Diurnal:
Less than 1% per 20
o
F (10
o
C (source/detector
dependent)
Sample Cell:
Stainless steel with Sapphire window
standard. Other materials available.
Cell Length:
.01 to 10 inches
Flow Rate:
50 to 1500 cc/min
Light Source:
Tungsten Mini-Lamp, optional Quartz Halogen
Sensitivity:
.015 to 3 absorbance units.
Reproducibility:
+/- 1% of scale or better
Filter Wavelength:
750nm to 5 microns, application dependant
Sample Pressure:
Sapphire window 250 psi
Response time:
Programmable
Other Specifications:
Ambient temp range: 32-122
°F
(0-50
°C)
Internal calibration: Optical span flag/zero and span calibration
NOTE: 5000B/5020B (sample temperature sensing and output correction)
Power Rating: 115/230 VAC, 50/60 Hz, Approx 200 watts
Readout Device: Digital, 2 line alphanumeric vacuum fluorescent display,
(VFD)
Analog Output Signal: 0-1 V (standard), 4-20mA isolated
Area Classification
Non-hazardous:Model 5000B
Hazardous / Explosion-proof:
Model 5020
5000B, 5020B Purge options:X, Y, Z purge, Cenelec IIB
AND H2 (PENDING) FOR ZONE I OR CLASS I, DIV I, B, C, D
AREAS
- 1220 - Multipoint flammable gas and vapor detection system (50 pages)
- 212R - Thermal conductivity analyzer (28 pages)
- 235 - Thermal conductivity analyzer (38 pages)
- 275R - Portable turbine generator purge gas analyzer (21 pages)
- 2000A-EU - General purpose thermal conductivity analyzer (86 pages)
- 2000XTC - Thermal conductivity analyzer (40 pages)
- 2010A - Split architecture thermal conductivity analyzer (110 pages)
- 2010B - Split architecture thermal conductivity analyzer (98 pages)
- 2020 - Explosion proof thermal conductivity analyzer (80 pages)
- 2120 - Trace Nitrogen in Argon Analyzer (66 pages)
- 2120XL - Trace Nitrogen Analyzer (85 pages)
- 2230R - Process Hydrogen Analyzer (26 pages)
- 2240 – Portable Handheld Hydrogen Leak Detector, 3rd generation (updated 1/31/11) (30 pages)
- 2240 - Portable Handheld Hydrogen Leak Detector, 3rd generation (revision 2/29/08) (40 pages)
- 2240 – Portable Handheld Hydrogen Leak Detector, 2nd generation (13 pages)
- 2750 - Portable turbine generator gas analzyer (40 pages)
- 300P - Percent oxygen analyzer (24 pages)
- 306WA - Analog trace oxygen analyzer (46 pages)
- 311 - Portable trace oxygen analyzer (19 pages)
- 311D - Portable trace oxygen analyzer with digital meter (18 pages)
- 311XL - Portable trace oxygen analyzer (18 pages)
- 316RA / RB / RAD / RBD - Oxygen analyzers (24 pages)
- 319R - Oxygen analyzer (23 pages)
- 320 Series - Portable oxygen detectors (24 pages)
- 326, 327 and 328 - Oxygen analyzers (45 pages)
- 329R - Oxygen analyzer (22 pages)
- 335 - Analog control room monitor for personnel safety (24 pages)
- 356WA - Analog trace oxygen analyzer (42 pages)
- 3000MA - Paramagnetic oxygen analyzer (63 pages)
- 3000MA - Paramagnetic oxygen analyzer Addendum (2 pages)
- 3000MB - Paramagnetic oxygen analyzer (59 pages)
- 3000PA - General purpose percent oxygen analyzer (69 pages)
- 3000PAEU - General purpose percent oxygen analyzer (78 pages)
- 3000PB - Bulkhead mount percent oxygen analyzer (82 pages)
- 3000TA - General purpose trace oxygen analyzer (75 pages)
- 3000TA-EU - General purpose trace oxygen analyzer (89 pages)
- 3000TA-XLEU - Trace oxygen analyzer (108 pages)
- 3000TB - Bulkhead mount trace oxygen analyzer (78 pages)
- 3000TB-XL - Trace oxygen analyzer (78 pages)
- 3000ZA - Trace oxygen analyzer (81 pages)
- 3000ZA-3X - Trace oxygen analyzer (72 pages)
- 3000ZA2G - Zirconium oxide analyzer (72 pages)
- 3000 Ultra Trace - PPB oxygen analyzer (72 pages)
- 3010MA - Paramagnetic oxygen analyzer, includes 0-100% range (88 pages)
- 3010MA – Paramagnetic oxygen analyzer, no 0-100% range – (superceded) (88 pages)