beautypg.com

Teledyne 3010PAC - Split architecture percent oxygen analyzer (EU - CENELEC) User Manual

Page 58

background image

ii: Part II

Model 3010PAC Oxygen Analyzer

Teledyne Analytical Instruments

Table of Contents

1

Introduction

1.1 Overview ........................................................................ 1-1
1.2 Intrinsic Safe Barriers ..................................................... 1-1
1.3 Area Clasificationl .......................................................... 1-2
1.4 Cell Housing/Probe ........................................................ 1-2

2

Operational Theory

2.1 Introduction .................................................................... 2-1
2.2 Micro-Fuel Cell Sensors ................................................. 2-1

2.2.1

Principles of Operation ........................................... 2-1

2.2.2

Anatomy of a Micro-Fuel Cell ................................ 2-2

2.2.3

Electrochemical Reactions ..................................... 2-3

2.2.4

The Effect of Pressure ........................................... 2-4

2.2.5

Calibration Characteristics ..................................... 2-4

2.2.6

Micro-Fuel Cell “Class” ........................................... 2-5
2.2.6.1 Class A-3 Cell ............................................ 2-5
2.2.6.2 Class A-5 Cell ............................................ 2-5
2.2.6.3 Class B-1 Cell ............................................ 2-6
2.2.6.4 Class B-3 Cell ............................................ 2-6
2.2.6.5 Class C-3 Cell ............................................ 2-6
2.2.6.6 Hydrogen and/or Helium Service................ 2-6

3

Installation

3.1 Unpacking the Analysis Unit ........................................... 3-1
3.2 Mounting the Analysis Unit ............................................. 3-1
3.3 Installing the Micro-Fuel Cell .......................................... 3-2
3.4 Testing the System ......................................................... 3-2
3.5 Intrinsic Safety Barriers ................................................... 3-3
3.6 Remote Probe Connection ............................................. 3-5

4

Maintenance

4.1 Routine Maintenance ..................................................... 4-1
4.2 When to Replace a Cell .................................................. 4-1
4.3 Cell Warranty .................................................................. 4-2
4.4 System Self Diagnostic Test ............................................ 4-3