beautypg.com

Mixing and dispensing – Magnum Venus Plastech PUTTY UNIT User Manual

Page 24

background image

Putty Unit Operations Manual

Rev. 07/2012

Page | 24

Mixing and Dispensing:


1.

Attach Static Mixer assembly to outlet on dispensing head / gun, apply lubricant to threads prior to
attachment (see Fig. 34)

Fig. 34


2.

To build fluid pressure, on the Putty pump push the priming button (09188) located on the air manifold
(see figure 36).







Fig. 36






3.

While pushing the priming button in, slowly increase the Putty pump regulator, 30 to 40 psi as a
starting point. Once pump has come to a stop, release priming button.


4.

With the Dispense head / Gun closed and the Catalyst Pressure Dump valve closed hand prime
catalyst pressure to at least 200 psi (14bar).


5.

Pin top and bottom of the Catalyst Pump at the desired percentage.

6.

Install catalyst injector and mix chamber onto the gun, both pour and spray.

NOTE: Use a small amount of red grease on the mix housing threads before installing mix tube to
gun (pour and spray).