beautypg.com

Flushing, cleaning and shutdown – Magnum Venus Plastech PATRIOT CHOP CHECK IMP-PAT-CCP-MP-5 User Manual

Page 27

background image

Patriot Putty Unit Operations Manual

Rev. 08/2012

Page | 27

Flushing, Cleaning and Shutdown:


1.

When finished with dispensing, it is necessary to flush and clean mixer and mix housing.


2.

Open trigger the gun momentarily to allow the pump shafts to run to full down position


3.

Release the gun trigger.


4.

Position outlet of mixer into approved waste container


5.

Slowly open 3 way flush valve to air and allow air to purge for 4-5 seconds


6.

Then turn 3 way flush valve to solvent purge for 4-5 seconds


7.

Repeat steps 4 and 5


8.

We recommend at this point removing the mixer plug and mix housing from the front of the gun for
cleaning. Clean thoroughly and reinstall.

9.

If you are using a disposable mixer assembly check for blockages or hardened material build up
inside the mixer tube and replace as necessary. (see figure 20)



Fig. 20

10.

Turn main air “off” to system (see figure 7)

.

11.

Relieve the air pressure from the flush tank by lifting the relief valve ring.










Disposable Mixer

Mixer Plug