beautypg.com

Priming the unit, Priming of unit air and solvent – Magnum Venus Plastech PATRIOT CHOP CHECK IMP-PAT-CCP-MP-5 User Manual

Page 21

background image

Patriot Putty Unit Operations Manual

Rev. 08/2012

Page | 21

Priming the Unit:


Priming of Unit Air and Solvent:

1. Close the main inlet air valves on the main air manifolds (see fig. 7)






Fig. 7












2. Connect 1/2 inch main air supply to the Air Manifold (see fig. 7)

3. Turn all regulators counterclockwise to full off and close all ball valves on the unit

4. Make sure Ram / Air lift control levers are in “neutral” (see fig. 8)






Fig. 8







5. Open the recirculation valve on the catalyst manifold to the ON position (see figure 9).




Fig. 9



Connect the air supply to the
supplied fitting 1/2"npt.