Pre startup instructions – Magnum Venus Plastech PATRIOT CHOP CHECK IMP-PAT-CCP-MP-5 User Manual
Page 20

Patriot Putty Unit Operations Manual
Rev. 08/2012
Page | 20
10. Connect blue Catalyst Hose from the gun to the bottom of the catalyst manifold. (see fig. 6)
11. Connect the Catalyst Hose from the Catalyst Pump the side of the Catalyst Manifold. (see fig. 6)
12. Install the Relief Valve and Return Valve tubes into the top of the Catalyst Jug. (see fig. 6)
13. Install the tube from the Catalyst Seal to the top of the Catalyst Jug. (see fig.6)
14. Connect the Catalyst Feed tube from the Catalyst Jug outlet to the Catalyst Pump inlet. (see fig. 6)
15. Install the proper fitting into the Main Air Supply Ball Valve and connect the air supply. The Ball
Valve comes with a 1/2" NPT Female port. (see fig. 3)
Pre Startup Instructions:
1.
Check all hoses for wear or damage from shipping, replace if necessary.
2.
Check to be sure you have appropriate quantities of Resin/Putty and Catalyst to complete the job.
3.
Check and repair or replace any damaged items before starting a job.
4.
Be sure all fluid connections are tight, all catalyst fittings, all resin fittings, all solvent
fittings.