4. Re-attach the Lower Valve Body (6986) to the Upper Valve Body (6985) using

one of the Machine Screws (7057). Position the Lower Valve Body as shown
below and tighten the screw.

5. Apply air to the actuator to move the valve to the Purge position and fully expose

the seal as shown below.

6. Use IVX3 Tool A or B on the flats of the Seal Upper Insert (6978) to stop it

turning as you unscrew the Slotted Screw (7055) from the end of the Lower
Insert (6979).

7. Remove the Seal

– Hard Wearing (7052) from the Seal Upper Insert (6978) and

press out the Seal Lower Insert (6979) using the Machine Screw (7057).

8. Replace the O-Ring (6988) on the Seal Upper Insert (6978) and Seal Lower

Insert (6979) applying Red Grease (6706-2-1 1oz) to both.

9. Install the new Seal - Hard Wearing (7051) onto the Upper Insert (6978) and

install the Lower Insert (6979) into the end of the new Seal - Hard Wearing.

10. Apply a drop of removable thread lock compound to the end of the Slotted Screw

(7055) and thread it into the end of the Seal Upper Insert (6978). Use IVX3 Tool
A or B on the flats of the Seal Upper Insert to stop it turning as you tighten the
Slotted Screw.