IVx3 Injection Valve Manual

Rev. 03/2012

Page | 17

Connections:



Stand-Alone Injection Valve

When used as a stand-alone injection valve it, can be

remotely controlled. To put the IVX3 into Injection mode send a constant 6 bar (90psi)
air signal to the Injection Signal port. Remove the air signal and the valve will return to
the Off mode. To put the IVX3 into Purge mode send a constant 6 bar (90psi) air signal
to the Purge signal port. Again remove the air signal and the valve will return to the Off
mode.



















Valve Pressure Ratings:

Actuator air pressure: 6 bar (87 PSI)

– 7 bar (102 PSI).

Maximum fluid pressure (resin ports): 7 bar (102 PSI).


NOTE: Use clean filtered non-lubricated air to supply the signal ports of the
actuator.






Purge signal port

Inject signal port

Resin / Solvent Inlet

Resin / Solvent Outlet

Resin Injection Port