Magnum Venus Plastech UltraMAX VLS-2400 Series User Manual
Page 26

VLS-2400 Series Fluid Section Manual
Rev. 08/2013
Page | 26
Fluid Section Disassembly Procedures:
1. Remove the two Hex Head Bolts (F-HB-06C-104-GR8) from the Outlet Body (VLS-
2401).
2. Slide the Foot Valve Collar (VLS-2424), Foot Valve Body (VLS-2402) and Cylinder
(VLS-2408) down off the Piston Rod (VLS-2409); discard the two O-Rings (O-V-129).
3. Remove the Ball Stop (VLS-2420), 4 Lobed Ball Guide (VLS-2428) and
3/4” Chrome
Ball (VLS-2427). Discard the Chrome Ball.
4. Clean and inspect the ball seat area of the Foot Valve Body (VLS-2402).
5. Loosen Packing Nut (VLS-2407) and slide the Piston Rod (VLS-2409) out through
the bottom of the Outlet Body (VLS-2401).
6. Unscrew the Piston Body (VLS-2419) from the Piston Rod (VLS -2409). Remove the
1/2” Chrome Ball (VLS-2426) and the Piston Ball Spring (VLS-2414). Discard the
1/2” Chrome Ball.
7. Slide the Piston Cup Comp Ring (VLS-2429), the two Piston Cups (VLS-2415),
Piston Cup Spacer (VLS-2416) and the Piston Cup Backup (VLS-2417) from the
Piston Body (VLS-2419). Discard the Piston Cups.
8. Remove the Packing Nut (VLS-2407) from the Outlet Body (VLS-2401
). Use a 1/4”
Wooden Dowel to push the Guide Bearing (VLS-2403), Female Compression Ring
(VLS-2404), Packing Set Assembly (VLS-2405), Male Compression Ring (VLS-
2406) and Wave Spring Assembly (VLS-2410) through the top of the Outlet Body
(VLS-2401). Discard the Packing Set Assy.
9. Clean and inspect all parts that will be reused, replace as needed.