beautypg.com

Magnum Venus Plastech UltraMAX VLS-2400 Series User Manual

Page 26

background image

VLS-2400 Series Fluid Section Manual

Rev. 08/2013

Page | 26

Fluid Section Disassembly Procedures:

1. Remove the two Hex Head Bolts (F-HB-06C-104-GR8) from the Outlet Body (VLS-

2401).


2. Slide the Foot Valve Collar (VLS-2424), Foot Valve Body (VLS-2402) and Cylinder

(VLS-2408) down off the Piston Rod (VLS-2409); discard the two O-Rings (O-V-129).


3. Remove the Ball Stop (VLS-2420), 4 Lobed Ball Guide (VLS-2428) and

3/4” Chrome

Ball (VLS-2427). Discard the Chrome Ball.


4. Clean and inspect the ball seat area of the Foot Valve Body (VLS-2402).

5. Loosen Packing Nut (VLS-2407) and slide the Piston Rod (VLS-2409) out through

the bottom of the Outlet Body (VLS-2401).


6. Unscrew the Piston Body (VLS-2419) from the Piston Rod (VLS -2409). Remove the

1/2” Chrome Ball (VLS-2426) and the Piston Ball Spring (VLS-2414). Discard the
1/2” Chrome Ball.


7. Slide the Piston Cup Comp Ring (VLS-2429), the two Piston Cups (VLS-2415),

Piston Cup Spacer (VLS-2416) and the Piston Cup Backup (VLS-2417) from the
Piston Body (VLS-2419). Discard the Piston Cups.


8. Remove the Packing Nut (VLS-2407) from the Outlet Body (VLS-2401

). Use a 1/4”

Wooden Dowel to push the Guide Bearing (VLS-2403), Female Compression Ring
(VLS-2404), Packing Set Assembly (VLS-2405), Male Compression Ring (VLS-
2406) and Wave Spring Assembly (VLS-2410) through the top of the Outlet Body
(VLS-2401). Discard the Packing Set Assy.


9. Clean and inspect all parts that will be reused, replace as needed.