beautypg.com

Magnum Venus Plastech UltraMAX VLS-2400 Series User Manual

Page 20

background image

VLS-2400 Series Fluid Section Manual

Rev. 08/2013

Page | 20

j. Cut the ½ inch diameter poly line, with the clamps, to 26 inches long. Clamp one end to

the outlet of the catalyst jug and the other end to the inlet of the catalyst pump. Make
sure clamps are airtight.

k. Connect the ¼-inch poly line to the relief valve on the catalyst manifold assembly and

insert the other end into the hole in the top of the catalyst jug.

l. Connect the ¼-inch poly line to the catalyst recirculation valve on the catalyst manifold,

and insert the other end into the hole in the top of the catalyst jug.


8.

Check all components for damage.