Magnum Venus Plastech PATRIOT 10:1 ADHESIVE SYSTEM User Manual
Page 20
Patriot 10:1 Adhesive System Operations Manual
Rev. 03/2014
Page | 20
Controls Continued:
Activator Pump Pressure Gauge & Regulator: used to regulate the pressure to the Adhesive pump
powerhead and thus fluid pressure.
Activator Pump Priming Button: used to activate the pump with pulling the trigger on the gun
Activator Ram Extraction Pressure & Regulator: used to set and monitor the air pressure being used
to push the ram piston out of the pail of material. This air is injected between the ram piston and
adhesive to push the pail down and the piston up and out of the pail.
Activator Ram Extraction On/Off Valve: turns On/Off the air pressure for Ram Extraction
Activator Ram Pressure Gauge & Regulator: used to set and monitor the air pressure for the Ram
pistons
– pressure pushing the piston down / up for the adhesive pump.
Activator Ram Direction Control: applies the pressure to remove or push the piston into the adhesive
material. There are three positions Up, Off and Down.
Activator Ram Extraction
Pressure & Regulator
Activator Ram
Extraction On/Off Valve
Activator Pump Pressure
Gauge & Regulator
Activator Priming
Button
Activator Ram Direction
Control
Activator Ram Extraction
Pressure Gauge and Regulator
Figure 8
Figure 9