beautypg.com

Magnum Venus Plastech PATRIOT 10:1 ADHESIVE SYSTEM User Manual

Page 20

background image

Patriot 10:1 Adhesive System Operations Manual

Rev. 03/2014

Page | 20

Controls Continued:



















Activator Pump Pressure Gauge & Regulator: used to regulate the pressure to the Adhesive pump
powerhead and thus fluid pressure.

Activator Pump Priming Button: used to activate the pump with pulling the trigger on the gun

Activator Ram Extraction Pressure & Regulator:
used to set and monitor the air pressure being used
to push the ram piston out of the pail of material. This air is injected between the ram piston and
adhesive to push the pail down and the piston up and out of the pail.

Activator Ram Extraction On/Off Valve: turns On/Off the air pressure for Ram Extraction

Activator Ram Pressure Gauge & Regulator: used to set and monitor the air pressure for the Ram
pistons

– pressure pushing the piston down / up for the adhesive pump.


Activator Ram Direction Control: applies the pressure to remove or push the piston into the adhesive
material. There are three positions Up, Off and Down.



















Activator Ram Extraction

Pressure & Regulator

Activator Ram

Extraction On/Off Valve

Activator Pump Pressure
Gauge & Regulator

Activator Priming
Button

Activator Ram Direction

Control

Activator Ram Extraction

Pressure Gauge and Regulator

Figure 8

Figure 9