APPENDIX B: SCAMP FUNCTION TABLE

“0/1” Jumper Set in Position “0”

Function

Switch

Setting

Displayed Value

0

Gross k-Factor (gross metering mode).

1

Linear F compensation parameter and current temperature in degrees Fahrenheit.

2

Linear C compensation parameter and current temperature in degrees Celsius.

3

Table 24 compensation parameter and current temperature in degrees Fahrenheit.

4

Table 54 compensation parameter and current temperature in degrees Celsius.

5

Table 54A compensation parameter and current temperature in degrees Celsius.

6

Table 54B compensation parameter and current temperature in degrees Celsius.

7

Table 54C compensation parameter and current temperature in degrees Celsius.

8

Table 54D compensation parameter and current temperature in degrees Celsius.

9

Table 6B compensation parameter and current temperature in degrees Fahrenheit.

A

Current temperature in degrees Celsius. (NH

3

compensation is active)

B

Seven segment display test.

C

Temperature Offset Adjustment and Current Adjusted Temperature. The
temperature is displayed in Celsius or Fahrenheit depending on the temperature
scale selected.

D

Serial Programming Mode (consult factory)

E

Last recorded disabling error number.

F

Electromechanical pulse output scale factor.


“0/1” Jumper Set in Position “1”

Function

Switch

Setting

Displayed Value

0

Flow rate and percent error for linearization point # 0.

1

Flow rate and percent error for linearization point # 1.

2

Flow rate and percent error for linearization point # 2.

3

Flow rate and percent error for linearization point # 3.

4

Flow rate and percent error for linearization point # 4.

5

Flow rate and percent error for linearization point # 5.

6

Flow rate and percent error for linearization point # 6.

7

Flow rate and percent error for linearization point # 7 .

8

Flow rate and percent error for linearization point # 8.

9

Flow rate and percent error for linearization point # 9.

A

Flow rate and percent error for linearization point # A.

B

Flow rate and percent error for linearization point # B.

C

Flow rate and percent error for linearization point # C.

D

Flow rate and percent error for linearization point # D.

E

Flow rate and percent error for linearization point # E.

F

Flow rate and percent error for linearization point # F.