beautypg.com

Liquid Controls SCAMP User Manual

Page 16

background image

16

APPENDIX A: SPECIFICATIONS


SCAMP SPECIFICATIONS
Circuit Board Dimensions………………………………………………………4” X 3”
Ambient Temperature Range…………………………………………...-30 to +75º C
Relative Humidity………………………………………….. 0-100% non-condensing
Weatherproof………………………………………………………………………None

(Circuit board is designed for installation in customer enclosure)

Non-incendiary UL and C-UL……………………Class I, Division 2, Groups C & D
Weights & Measures

USA………………………………………………………….NIST Handbook 44

Canada (pending)..…………………………………………SVM-1 and SVM-2

Electro-Magnetic Compatibility (EMC)………………….per CE mark requirements
SCAMP Power Supply……………………………….9 to 18 VDC @ 0.2A maximum
SCAMP Outputs……...Two Open Drain FETs for quadrature output (100mA, Sinking)
…………..(a jumper option is provided to make the B pulse an inverted A pulse

1

)

…………One Open Drain FET for electromechanical pulse/fault output (1A, Sinking)
……………………………………………………………………………....One RS-232
Wiring Termination………………………..……Unpluggable Screw Terminal Block

1

Needed for compatibility with certain dispenser heads. To convert the B pulse to an

inverted A pulse, reposition the jumper on the left side of SCAMP to the left-most
position (refer to diagram on page 4).