1.
Place the prox.pad plus unit in Program mode.
Press:
99 # Master Code * (default is 1234)]
A slow blinking yellow LED indicates that the unit
is in Program mode. A steady yellow LED, in
contrast, means that errors were detected during
programming. Error states can be cleared by press-
ing the asterisk * key.
2.
Hold the PDA up to the prox.pad plus IR port
steadily (about one or two inches away; the IR
port is located to the right of the yellow LED) and
then press:
25 # 0 # 0 # **
3.
When the list is complete, press * to exit Program
mode. Refer to the DCD software instructions for
details.
By default, this command dumps all users, includ-
ing empty user locations. The user dump select
option (command 30, option 17) lets you change
this. If you enable option 17, only programmed
users are dumped. To enable, press:
30 # 17 # 1 # **