OPERATION AND MAINTENANCE
» MAINTENANCE + BATTERY
MAINTENANCE
Disconnect all power to the operator before servicing.
CHECK AT LEAST ONCE EVERY
DESCRIPTION
TASK
MONTH
6 MONTHS
3 YEARS
External Entrapment Protection System
Check and test for proper operation
X
Photoelectric Sensors
Check and test for proper operation
X
Warning Signs
Make sure they are present
X
Manual Disconnect
Check and test for proper operation
X
Sprockets and Chains
Check for excessive slack and lubricate
X
Gate
Inspect for wear or damage
X
Accessories
Check all for proper operation
X
Electrical
Inspect all wire connections
X
Chassis Mounting Bolts
Check for tightness
X
Operator
Inspect for wear or damage
X
Batteries
Replace
X
NOTES:
• Severe or high cycle usage will require more frequent maintenance checks.
• It is suggested that while at the site voltage readings be taken at the operator.
Using a digital voltmeter, verify that the incoming voltage to the operator it is
within ten percent of the operator’s rating.
BATTERY
The battery should be replaced every three years. Use only LiftMaster part 29-NP712
for replacement batteries. The operator comes with one 7AH battery. A second 7AH
(29-NP712) battery may be added or one 33AH (A12330SGLPK) may be used in
place of the 7AH batteries. The batteries contain lead and need to be disposed of
properly.