beautypg.com

Ram 300, Concrete pad construction, Installation specifications – Controlled Products Systems Group RAM300 User Manual

Page 8

background image

RAM 300

RAMSET

6

www.ramsetinc.com

Gate Opened

CONdUIT FOR ELECTRIC POWER

CONdUIT FOR MASTER/SLAVE

CONdUIT FOR COMMUNICATION

Steel Square Tubing

4x4

STANDARD

INSTALLATIONS

Gates From: 8’-16’ (18”)

Gates From 16’-22’ (24”)

Inside

Property

Outside

Property

14”

2 1/2”

20”

6 3/4”

26”

13”

CONCRETE PAD CONSTRUCTION

Dimensions given for the pad are based
on soil bearing shear of 2000 P.S.F. These
figures may have to be adjusted
depending on local soil conditions.

1. Construct form for mounting pad

according to dimensions shown
in Figure 1 and 2.

2. Locate mounting pad according to

dimensions given in illustration.

3. Level top edge of form.

4. Set reinforcing bars and wire mesh.

5. Allow pad to cure for 48 hours,

and remove forms.

6. Note: conduits 6” above concrete pad.

INSTALLATION SPECIFICATIONS

Figure 1

18”

18”

25”

24”

Allow 2” above

ground level

minimum for

leveling.

ground Level

ground Level

DEDICATED CONDUIT

WITH 15 amp BREAKER

1/2” REDHEAD

ANCHOR BOLTS 4x

INDEPENDENT CONDUIT

FOR LOW VOLTAGE

WIRES

ELECTRICAL

CONDUIT FOR

MASTER/SLAVE

Figure 2