Troubleshooting, Solutions, Ts ref# check page ref – Controlled Products Systems Group ECUMSING5 User Manual
Page 37

VIKING TECHNICAL SUPPORT 1.800.908.0884
3 5
TROUBLESHOOTING
Solutions
Begin the troubleshooting process by referring to the error messages on the LCD
Display and/or the Status LEDs on the control board. Use pages 30-34 to identify
the Troubleshooting Reference # (TS Ref#) then reference the table below.
TS Ref# CHECK
Page Ref#
1
Check that the high voltage power supplied to “EMI Board” is within range.
100v-120v or 200v-240v
pg. 14
2
Remove and check EMI Fuse for continuity.
pg. 14
3
Check that the “Voltage Selector”, on the EMI Board, is set according to the high
voltage power supply. 115v AC or 230v AC
pg. 14
4
Not applicable to this model
5
Check that the Power Harness is connected to the control board.
pg. 4, 14
6
Check that the limit circuits are Normally Closed (N.C.). Check the limit switch.
7
Check Motor Fuse on the control board.
pg. 4
8
Check that the operator is not in Manual Release mode
9
Check the Status LEDs to determine if the control board is receiving an input
from any external devises or if the “ODS” has been triggered.
pg. 20,
22-25,
30-31
10
Remove the external devices from the control board to determine if the control
board is responding to an input or problem with the external device or wiring.
pg. 22-25,
30-31
11
Check the “ODS” setting on the control board.
pg. 12, 20
12
Check that the gate can be move manually with low resistance throughout its
full range of motion.
pg. 8
13
Check the limit position.
14
Not applicable to this model
15
Check the EMI cable is properly connected to the “EMI” Connector on the
control board.
pg. 4
16
Check the LCD Display for Error Messages
pg. 34
17
Not applicable to this model
18
Check 4 Amp fuse on the control board
pg. 4
19
Manually adjust any setting on the Control Board to clear all wireless override
settings
20
Check for 24VAC out from the Toroidal Transformer and Power Harness
pg. 4, 14
?
The Control Board or EMI board may be damaged. Call Viking Techical Support