Troubleshooting, Led references, Led status meaning page 35 ts ref#(s) – Controlled Products Systems Group ECUMSING5 User Manual

Page 32

background image

VIKING TECHNICAL SUPPORT 1.800.908.0884

3 0

LED References

In addition to the LCD Display, the control board LEDs monitor the various circuits of the
control board. Use the table below to identify the corresponding “TS Ref#” and refer to
page 32-35 for further troubleshooting.

TROUBLESHOOTING

# LED

Status

Meaning

Page 35

TS Ref#(s)

1

“Magnetic
Lock”

OFF

At Closed Limit and Magnetic Lock Relay state is closed across “COM” &
“N.C”. (page 27). Gate should be at the Close Limit.

SOLID

Not at Closed Limit and Magnetic Lock Relay state is closed across “COM” &
“N.O”. (page 27). Gate should not be at the Close Limit

2

“Check Motor” OFF

Normal Condition.

SOLID

The control board is sending power to the motor but this circuit is not
complete or closed.

7, 8

3

“Battery Low” OFF

Normal Condition.

SOLID

Batteries are low. Check power supply to the operator. (pages 14-15).

1, 2

FLASHING

Batteries critically low. Check power supply to the operator. (pages 14-15).

1, 2

4

“POWER”

SOLID

Normal Condition.

FLASHING

Operator is running on batteries only (pages 14-15).

1, 2

OFF

No power to control board.

1, 2, 4, 5

5

“Radio”

OFF

Normal Condition.

SOLID

Control Board is receiving an input from a device connected to the
Radio terminal (pages 23, 36).

9, 10

6

“UL”

OFF

Normal Condition.

SOLID

Control Board is receiving an input from a device connected to the UL
terminal (pages 12-13, 36).

9, 10

7

“Re-Open”

OFF

Normal Condition.

SOLID

Control Board is receiving an input from a device connected to the Re-
Open terminal (pages 22, 25, 36).

9, 10

8

“ATG”

OFF

Normal Condition.

SOLID

Control Board is receiving an input from a device connected to the ATG
terminal (pages 24, 36).

9, 10