beautypg.com

Different ul 325 class types – Controlled Products Systems Group AOMSL90DC User Manual

Page 5

background image

Class one: Residential

A vehicle gate operator intended for use at a home of one to four single family dwellings,
garages or parking area.

Class Two: Commercial or General Public Access

A vehicular gate operator intended for use at a commercial location or building such as a
multi-family housing unit (five or more single family units), hotel, garages, retail stores,
other buildings servicing the general public.

Class three: Industrial or limited Access

A vehicular gate operator intended for use at an industrial location or building such as a
factory, loading dock area, or other locations not intended to service the general public.

Class Four: Restricted Access

A vehicular gate operator intended for use at a guarded industrial location or building
such as airport security areas or other restricted access locations not servicing the
general public where unauthorized access is prevented via supervision by security
personnel.

Other components required to satisfy UL 325

Each class must have a primary and secondary means to sense and react to
obstructions within two seconds.

The six types of obstruction sensing systems are:

Type A:
Inherent obstruction sensing system. This system must sense and initiate the reverse of
the gate within two seconds of contact with a solid object.

Type B 1:
Provision for connection of a non-contact device can be used, such as a secondary
protection.

Type B2:
Provision for connection of a contact sensor. Examples include an edge device or
equivalent. This can be used for secondary protection.

Type C:
Inherent adjustable clutch or pressure relief valve.

Type D:
Provision for connection of or provided with and actuation device requiring continuous
pressure.

DIFFERENT UL 325 CLASS TYPES

4