MASTER/SLAVE CONNECTION

Use a two wire

and run it through a UL listed conduit for

master/slave connection. Follow the wiring diagram as shown below.

shielded cable

Master Board

Slave Board

+.....................Positive to Positive...................+

-...................Negative to Negative...................-

Before connecting master/slave gate operators together, test and adjust

limit

switches and the ERDs for each operator as “

” machines. All

accessories must be installed on the master board, no exception.

the

stand alone

See page 53 for dip switch settings.

Connect shield to
slave metal frame
only.

Use UL listed
conduit

Shielded
cable