Multiple safety devices hookup, Multiple safety devices connections, Wire nut – Controlled Products Systems Group AOMSW300 User Manual
Page 19: Safety wire connections, Terminal strip
33
ON
514
GDE
ON
514
GDE
ON
514
GDE
ON
514
GDE
ON
514
GDE
ON
514
GDE
ON
514
GDE
Power
Detect
Loop Fail
Loop Fail
Reset
Reset
2
1
0
0
SENS.
LEVEL
BOOST ON
PULSE
FREQ.
0
0
OFF
PRES
2
1
1
2
3
4
5
6
SAFETY Loop
detector
PHOTO
Beam
Relay (COM)
Relay (COM)
Relay (N.C.)
Relay (N.C.)
MULTIPLE SAFETY DEVICES
CONNECTIONS
Multiple
devices installed together must be connected
.
the normally closed (N.C.) dry contact from
accessory relay.
efore
installing the accessory devices, remove the black wire jumper from the
terminal position
in series
SAFETY
“
”
SAFETY
Locate
each
Also, b
on the terminal strip of the control board.
From Accessory #1 to Terminal Strip
Relay Com
to 24V-COM
From Accessory #2 to Terminal Strip
Relay N.C.
to SAFETY
From Accessory #1 to Accessory # 2
Relay N.C.
To Relay Com
This diagram is for the relay wires of the safety devices, two wires to the terminal
strip (one from each device) and two wires to the orange wire nut.
Wire nut
Terminal strip
Safety wire connections
AB
Remove black jumper
from SAFETY when
a safety device is
installed.