background image

25

ON

514

GDE

ON

514

GDE

ON

514

GDE

ON

514

GDE

ON

514

GDE

ON

514

GDE

ON

514

GDE

RIGHT HAND OPENING

See chart below for specific operator model wiring direction.

Opening to the right

IMPORTANT:

This setting is for
right hand opening.
Be sure to follow the
wire sequence as the
two Swinger models
are the opposite of
each other.

Motor wires

SW-300

SW-300

SW-350

SW-350

Limit wires

C-LIMIT =

Blue

wire

Blue

wire

Blue

wire

Blue

wire

MOT-CLOSE =

C-LIMIT =

MOT-CLOSE =

O-LIMIT =

MOT-OPEN =

O-LIMIT =

Red

wire

Red

wire

Red

wire

Red

wire

MOT-OPEN =

Use these wire settings for SW-300 & SW-350 opening direction

.